x
Envie sua pergunta hoje
Rápida citação

Commercial Peak Shaving Energy Storage Solution

Control peak grid demand with a battery energy storage system sized around your facility’s load, tariff, transformer capacity and operating schedule. Charge during off-peak periods and discharge when demand approaches the preset limit to reduce demand charges and improve energy cost control.

  • Load-based demand limit control
  • Integrated battery, PCS, EMS and BMS
  • Configurable power and storage capacity
  • Engineering based on your site data

Why Are Your Peak-Demand Charges So High?

A short demand spike can set your monthly peak. Common causes include simultaneous equipment operation, demand-based tariffs and a lack of automatic load control.

Peak-Loads-Exceed-Average-Demand

Peak Loads Exceed Average Demand

Brief demand spikes can determine the facility’s monthly billing peak.

Large-Loads-Run-at-the-Same-Time

Large Loads Run at the Same Time

Motores, HVAC and production equipment operating together can sharply increase grid demand.

Tariffs-Charge-for-Maximum-kW

Tariffs Charge for Maximum kW

Your bill may be based on the highest recorded demand, not only total energy consumption.

No-Automatic-Demand-Control

No Automatic Demand Control

Without EMS and battery response, site demand can exceed the preset grid limit.

Corte de Pico & Recheio de Vale?

Peak shaving lowers grid demand during peak periods, while valley filling stores energy when demand or electricity prices are low.

Corte de Pico

The battery discharges when facility demand approaches a preset grid limit. This reduces the maximum power imported from the grid and can lower demand charges.

Recheio de Vale

The battery charges during low-demand or lower-tariff periods. The stored energy can then support the facility during later peak-load periods.

How the Peak Shaving Battery System Works

The EMS charges the battery during low-demand periods and discharges it when facility demand approaches the preset grid limit.

24-hour peak shaving battery operation curve showing facility load, grid demand limit, battery charging and discharging

The battery charges during low-demand periods and discharges during peak-load periods to keep grid import below the preset demand limit.

Off-Peak Charging

The battery charges when facility demand or electricity prices are low.

Normal Operation

The grid supplies the facility while the battery remains ready.

Peak-Demand Control

The battery discharges to keep grid import below the preset demand limit.

Load Returns to Normal

The EMS stops discharging and prepares the battery for the next peak period.

Energy Storage Cabinets for Peak Shaving

Select the required power and battery capacity based on your peak load, peak duration, tariff structure and backup requirements.

30KW-60KWh-PV-energy-storage-system-from-HBOWA
  • Potência nominal: 20–50 kW
  • Capacidade nominal: 50–107 kWh
  • Maneiras de resfriamento: Resfriamento de ar
fabricantes de gabinete de armazenamento de energia de bateria de 100kwh na China
  • Potência nominal: 50 kW
  • Capacidade nominal: 100 kWh
  • Maneiras de resfriamento: Resfriamento de ar
260 Sistema de armazenamento de bateria KWh 125KW 215KWh 100KW
  • Potência nominal: 100 kW
  • Capacidade nominal: 215 kWh
  • Maneiras de resfriamento: Resfriamento de ar
261Armazenamento de energia comercial kWh 125KW
  • Potência nominal: 125 kW
  • Capacidade nominal: 261 kWh
  • Maneiras de resfriamento: Resfriamento de ar

Peak Shaving Energy Storage Projects

See how commercial and industrial facilities use battery storage to control peak demand, reduce electricity costs and improve power reliability.

Malásia-200kw-500kwh-sistema de armazenamento de energia de corte de pico

200 kW / 500 kWh Factory Peak Shaving Project

Malásia 200 kW 500 kWh

Corte de pico, gerenciamento de carga

View Project
50kw-448kwh-Sistema de bateria para barbear de pico na China

50 kW / 448 kWh Factory Peak Shaving Project

China 50 kW 448 kWh

Valley charging and peak-period discharge

View Project
50sistema de armazenamento de bateria kw-300kwh na Polônia

50 kW / 300 kWh Factory Energy Storage Project

Polônia 50 kW 300 kWh

Peak-demand control

View Project

What We Need to Design Your Peak Shaving Project

Share a few basic details about your facility and peak-load requirements. Our engineering team will use this information to recommend the appropriate system power, battery capacity and operating strategy.

Basic Project Information We Need

  • Project Location and Grid País, grid voltage and frequency.
  • Facility Load Maximum demand, typical operating load and peak-load duration.
  • Electricity Tariff Peak and off-peak prices or the latest electricity bill.
  • Project Goal Demand reduction, electricity cost savings, transformer relief or backup power.

What You Will Receive

  • Tamanho do sistema recomendado Suggested PCS power and battery capacity.
  • Operating Strategy Battery charging, discharging and demand-limit settings.
  • System Configuration Recommended cabinet, metro, EMS and electrical components.
  • Technical Proposal System specifications, layout guidance and commercial quotation.

Start Your Peak Shaving Project

Send us your facility information and peak-load requirements. Our team will review the project and recommend a suitable battery energy storage solution.

Request a Project Design

Obtenha suas soluções solares personalizadas com HBOWA

Atualizar preferências de cookies
Role para cima